TECHNICAL DATASHEET

PM In-Line Fiber Optic Attenuator (IFOA, Polarization Maintaining)

High-precision In-Line Polarization-Maintaining Fixed Optical Attenuator (PM IFOA) providing calibrated attenuation (1 dB to 30 dB) while preserving input polarization with high extinction ratio (>20 dB) across 780nm to 1550nm wavelengths.

Technical Specifications

Parameter
Specification
Unit
Center Wavelength
1550, 1310, 1064, 980, 850, 780
nm
Operating Bandwidth
±20 (1310/1550), ±10 (780-1064)
nm
Attenuation Values
1, 2, 3, 5, 10, 15, 20, 25, 30
dB
Attenuation Tolerance
±0.5 (1-10dB), ±1.0 (11-30dB)
dB
Min. Extinction Ratio @ 23°C
20 (Both axes) / 22 (Fast axis blocked)
dB
Min. Return Loss
50
dB
Max. Optical Power (CW)
500
mW
Fiber Type
PM Panda Fiber on both ends
-
Operating Temperature
-20 to +70
°C
Storage Temperature
-40 to +85
°C
Package Dimensions
dia. 3.0 x 40 mm / dia. 3.0 x 54 mm / 58 x 10 x 8 mm
mm
Technical Datasheet Note
Hermetic stainless steel tube design ensures long-term environmental stability. With connectors, IL increases by 0.3 dB, RL decreases by 5 dB and ER decreases by 2 dB.
Configuration and ordering notes

Configuration parameters include operating wavelength, exact fixed attenuation value, and connector polish (FC/APC slow-axis keyed standard).

Selection Guidance: Need component selection assistance? Compare specifications and architectures across our full .

Key Applications

Coherent receiver dynamic range testing; Optical power leveling in PM fiber networks; Calibration of PM optical sensor systems.

Package Drawing

110 PM In-Line Fiber Optic Attenuator (IFOA, Polarization Maintaining), Center Wavelength: 1550, 1310, 1064, 980, 850, 780 – KernsOptic
Package reference for PM In-Line Fiber Optic Attenuator (IFOA, Polarization Maintaining). Confirm the final configuration during engineering review.

Package dimensions depend on the configuration. The catalog, ordering information or drawing show different package references; engineering must confirm the final mechanical outline before ordering.

Need an exact configuration?

A quotation review can begin with the application, quantity and available component information. Wavelength, optical power, fiber and termination details can be clarified with engineering.